Beacon best placement

warning

The beacon is resistant to water, but it must never be fully or partially submerged, or exposed to high-pressure water jets for long periods. Where the beacon can get wet, never mount it upside down, so that water cannot enter the casing. The warranty is void if the beacon is used incorrectly.

Where you put the beacon depends on what your location system does with it.

For BLE location (RTLS)​

  • Mount the beacon vertically on a wall or a pole, about 2 to 3 m above the floor.
  • Keep the space around the beacon as clear as possible: fewer obstacles between the beacon and the receivers give a more stable signal and a better accuracy.

For geozoning​

  • Place one beacon inside each room or zone to detect. Walls help to keep the signal inside the zone.
  • The beacon can be mounted on a wall (2 to 3 m high) or on the ceiling, in a dry indoor room only (see the warning above).
  • Adjust the transmit power to the size of the zone. A lower power keeps the signal inside the room and avoids detections from neighbouring zones. See the TX power table, then set the value with the Beacon configuration tool. A lower power also saves battery.

In all cases​

  • Fix the beacon with screws, double-sided tape or a magnet. If you use a magnetic mount, keep it away from the reed switch (marked by the arrow on the casing), or it may trigger the magnet sequence.
  • Keep at least five centimetres between the beacon and metallic objects or magnets.
  • Avoid strong radio interference, such as a mobile phone placed right next to the beacon.
  • Mounting the beacon vertically or on the ceiling does not affect its LoRaWAN connection. It still needs to reach a gateway.